Showing posts with label electric showers. Show all posts
Showing posts with label electric showers. Show all posts

3 May 2012

How To Fit A Shower

How To Fit A Shower


How To Fit A Shower - Brief Guide


If you've ever been the victim of a sudden surge of hot or cold water when taking a shower with a traditional mains fed shower when an unsuspecting family member turns on another tap in the house, or flushes the loo whilst you're showering you will hopefully soon benefit from the luxury of constant temperature waterflow which comes from fitting a thermostatic shower, using our handy step by step guide to fitting a shower.

Different Types Of Thermostatic Mixer Showers


There are two main types of thermostatic mixer showers available, although there are many variations upon these two main categories of mixer showers - the first main type of thermostatic mixer shower is a surface-mounted mixer shower. Essentially, surface mounted mixer showers fit to the surface of the wall and so does the pipework - i.e the pipework is not embedded in the wall behind plasterwork or embedded in brickwork.

The second main type of mixer shower is a recessed mixer shower. Recessed mixer showers have their pipework recessed into the wall with plasterwork and tiling fitted between the pipework and the thermostatic shower itself.

Our step by step guide to fitting your thermostatic shower includes a complete list of the tools and materials you will need to carry out your DIY shower fitting project.

Tools Needed To Fit A Shower


Quality spirit level
Drill suitable for drilling tiles - i.e. tile drill
A spanner - adjustable spanner preferably
Measuring tape
Pencil for marking out
Pipe cutters suitable to cut copper pipe or plastic water pipe
Dust sheets to keep the area clean

Materials You Need To Fit A Shower


Shower shut-off valves / isolating valves
15mm plastic pipe
15mm copper pipe
A selection of tees and elbows in copper and plastic
Thermostatic mixer shower
Shower head for mixer showers
Fitting Your Shower

Where Will You Get Your Hot And Cold Water Supply From For Your Shower?


Before you start to fit your shower you will need to think about where you are going to bring the shower water supply from. You can choose to either bring the water supply from the bath below by tapping into the taps using plumbing tees and elbows or you can bring the water supply from a nearby shower cubicle. If you decide to bring the water supply from a shower cubicle you will normally find a suitable pipework tee point below the floorboards. If in doubt about where the pipework is running, switch on the water to your selected watersource (i.e. the taps to the bath or the shower cubicle) and trace the flow of water back to a suitable point to tee in, as the water is running through the pipework. Obviously the hot water pipe will be warm.

Turn off the water supply at the stopcock


Once you have identified where you are going to bring your new shower's water supply from, it's time to switch off the main water supply at the stopcock. Just in case there is water already in the pipework and to prevent water leakage, you should turn on all the taps to run off any remaining water which is still in the system.

Run the pipework to the shower


With the water turned off at the main stopcock and any remaining water emptied from the system, you can start running your pipework to the site of the new shower. You can use either plastic piping or copper piping to run the pipes to the shower. Plastic piping is easier for the DIY plumber to work with but you should be careful to avoid leaks in plastic piping by fitting pipe inserts between joints and fit copper fittings at the end of the pipework for increased leak prevention. Remember to fit isolating valves at the end of the pipework as near to the shower as possible without being intrusive or cosmetically unattractive. Isolating valves might very well come in handy if your shower or pipework springs a leak. With an additional water shut-off point near your shower you will not need to rely as much on the main water stopcock.

Flush the new pipework through


To avoid damaging thermostatic shower valves you should ensure that the pipework does not have any dirt or grit in it. Flush the pipework through to check this.

Measure where the shower valve will go


Hold the valve against the wall and check how much pipework length will be required to ensure the new thermostatic valve can fit flush.

Cut the hot and cold water outlet pipes to the right length
Once you have ascertained how much pipework is needed to fit the thermostatic shower valve you can cut the hot and cold water pipes for the shower using pipe cutters.

Make the holes for the thermostatic valve


Drill the holes in the wall to fit your thermostatic shower valve. If you are drilling into tiles ensure that your drill bit is suitable to work on tiling. Use a spirit level to fit any bracket or wall fitment flush to the wall to prevent problems when fitting the shower valve and to avoid damaging tiling or plasterwork.

Fit compression olives into each of the water inlets

For additional leakage prevention fit a compression olive and nip it up snugly.

Align the shower valve

Mark up the wall for the shower valve fitting taking care.

Fit the shower riser rail


Assess how high you want the shower riser rail. Use a spirit level to mark vertically up the wall from the valve position to the height you would like the shower head to be. If in doubt, for further assessment, stick masking tape to the wall vertically replacing the spirit level and take it to the point where the shower head will be. Step back and check that the shower head will be in the correct position using the masking tape as an indication of the shower riser rail. Once you are confident that the shower riser rail will be in the correct position, cut the shower riser rail and run the pipework up the riser rail.

Fit the shower head to the riser rail and test for leaks


The penultimate step to fitting your new shower is fixing the shower head at the top of the riser rail. Turn your new shower on and check the shower for leaks.

Checking The Shower Thermostat Works


Ensure that the thermostat kicks in by turning on the hot and cold water taps whilst checking that the temperature of your newly fitted shower stays constant as expected.

Your New Shower Is Fitted


A new thermostatic shower fitted. Enjoy your new shower!

Need A Plumber To Fit A Shower?


If you decide that fitting a shower is not for you why not use Top Tradespeople's free quotes service to find a local plumber.

Find a plumber to fit a shower

29 Apr 2012

Working With Electrics In Bathrooms And Showers

Working With Electrics In Bathrooms And Showers

When you are getting electrical work done in the bathroom, it is important to understand the implications of the Part P of the Building Regulations. If a homeowner is getting electrical work done in the bathroom, they must comply with Part P by either using a Competent Persons Scheme electrician, or by submitting a Building Regulations application to the Local Authority. However, in most cases the simplest and most economical method of accomplishing this is to have the electrical installation work performed by a qualified electrician registered with an authorized Part P Competent Person Scheme. If you use this method, the electrician will not only perform and test the electrical work, but also notify the appropriate authorities. If you choose a different method, you will still have to pay to have the electrical work to be inspected. It is often much less expensive to just have a Competent Person perform the entire electricians job.

Electricians - What is a Competent Person?

The term "Competent Person" refers to a firm that has been approved by one of the Part P schemes approved by the government as being competent to self-certify that any electrical work performed complies with the Building Regulations. Part P was introduced to reduce the number of fires, injuries and deaths caused by electrical installations that were performed in a faulty fashion. There are several advantages to using a "Competent Person". For example, you will have the option of taking out an insurance-backed guarantee for the work that is being performed, you won't have to pay Building Control charges, and if you are not happy with the work that was performed, you will have access to a formal complaint procedure.

Electricians - Electrics in the Bathroom

For the purpose of wiring regulations, the bathroom is divided into zones that range from Zone 0, which is the wettest, which is an area that actually can hold water, such as the interior of the bath or shower, to Zone 2. Electrical equipment is rated in regards to its level of mechanical and moisture protection. If the equipment doesn't an an IP number, it cannot be used in these zones, or anywhere else that has a wet or damp environment, for that matter. Some of the typical bathroom electrical items that have these IP numbers include lighting, heaters, extractor fans, shower pumps, and electrical shower units.

Electricians - Electricians and Electric Showers

If you are planning to install an electric shower, which is installed as a wall unit using an electric element to heat the water, it is advisable to have this work done by an qualified electrician with an authorized Part P Competent Person Scheme. While electric showers are quite popular and convenient, they can be dangerous if they are installed incorrectly. There are regulations about electric showers and their installation that are simply best handled by an electrician. The installation for these units varies, depending on the model that is being installed, so an electrician will not only be aware of the proper method, but also knowledgeable concerning the regulations about electric showers and their installation.